Cone & Plate System That's Perfect For QC
Brookfield will
configure the NEW CAP 1000+ Viscometer to your application.
Features And Benefits
-
Quick Single Point Test
-
Choice of Shear Rate
-
Rapid Temperature Control
-
Meets Industry Standards: ASTM
D4287, ISO 2884, BS 3900
-
Shear Rates as High as 10,000
sec-1
-
New Compact Size (fits easily on
test bench)
-
Rugged Design Can Handle
Production Environment
-
Small Sample Size, < 1 mL,
Simplifies Testing
-
Easy to Clean
-
Customizable options
-
Parallel printer output
Let Us Configure The CAP 1000+
To Provide A Simple, Single Point, Viscosity Test
-
Specify one speed or shear rate
-
Indicate viscosity range
-
Select the
temperature range that best suits your application:
5ºC-75ºC or 50ºC-235ºC
-
Choose from 10 spindles for
multiple viscosity ranges
-
Brookfield will help
choose the appropriate instrument configuration.
Applications
-
Paints & Coatings
-
Adhesives & Sealants
-
Polymers & Resins
-
... many more
Ranges
Spindle |
Shear
Rate
(sec-1) |
Sample
Volume |
Viscosity
5 RPM
(Poise) |
Viscosity
50 RPM
(Poise) |
Viscosity
500 RPM
(Poise) |
Viscosity
750 RPM
(Poise) |
Viscosity
900 RPM
(Poise) |
CAP-01 |
13.3 N |
67µL |
37.5-375 |
3.75-37.5 |
0.375-3.75 |
0.25-2.5 |
0.2-2.0 |
CAP-02 |
13.3 N |
38µL |
75-750 |
7.5-75 |
0.75-7.5 |
0.5-5 |
0.41-4.1 |
CAP-03 |
13.3 N |
24µL |
150-1500 |
15-150 |
1.5-15 |
1-10 |
0.83-8.3 |
CAP-04 |
3.3 N |
134µL |
300-3000 |
30-300 |
3-30 |
2-20 |
1.67-16.7 |
CAP-05 |
3.3 N |
67µL |
600-6000 |
60-600 |
6-60 |
4-40 |
3.33-33.3 |
CAP-06 |
3.3 N |
30µL |
1500-15000 |
150-1500 |
15-150 |
10-100 |
8.3-83 |
CAP-07 |
2.0 N |
1700µL |
62.5-625 |
6.25-62.5 |
0.625-6.25 |
0.42-4.2 |
0.35-3.5 |
CAP-08 |
2.0 N |
400µL |
250-2500 |
25-250 |
2.5-25 |
1.66-16.6 |
1.4-14 |
CAP-09 |
2.0 N |
100µL |
1000-10000 |
100-1000 |
10-100 |
6.67-66.7 |
5.5-55 |
CAP-10 |
5.0 N |
170µL |
100-1000 |
10-100 |
1-10 |
0.67-6.7 |
0.5-5.0 |
|
Cone
& Plate System That's Perfect For R&D and QC
Brookfield's NEW design offers
expanded temperature and viscosity ranges as well as a new
easy-to-use interface... all in a smaller, more compact instrument.
The CAP2000+ now
offers lower shear rates, making it suitable for many
applications where small sample volume and good temperature
control are necessary. And the rugged, easy-to-use design
make it perfect in environments where other instruments
won't last.
Features And Benefits
-
Expanded Ranges
Viscosity:
|
0.2 - 15,000 Poise
|
Shear Rate:
|
10 - 13,000 sec-1
|
Temperature:
|
5-75ºC or 50-235ºC
|
Speed of Rotation:
|
5-1000 RPM
|
-
Small sample size
-
Integrated temperature control
-
NEW CAPCALC32
software for complete control and data analysis
-
Open system for quick and easy
cleaning
-
Meets Industry Standards: ASTM
D4287, ISO 2884, BS 3900
Applications
-
Paints & Coatings
-
Adhesives & Sealants
-
Polymers & Resins
-
... many more
Ranges
Spindle |
Shear
Rate
(sec-1) |
Sample
Volume |
Cone
Angle |
Cone
Radius |
Viscosity
Range
(Poise) |
CAP-01 |
13.3 N |
67µL |
0.45º |
1.511 cm |
0.2-375 |
CAP-02 |
13.3 N |
38µL |
0.45º |
1.200 cm |
0.41-750 |
CAP-03 |
13.3 N |
24µL |
0.45º |
0.953 cm |
0.83-1500 |
CAP-04 |
3.3 N |
134µL |
1.8º |
1.200 cm |
1.67-3000 |
CAP-05 |
3.3 N |
67µL |
1.8º |
0.953 cm |
3.33-6000 |
CAP-06 |
3.3 N |
30µL |
1.8º |
0.702 cm |
8.3-15000 |
CAP-07 |
2.0 N |
1700µL |
3.0º |
2.399 cm |
0.35-625 |
CAP-08 |
2.0 N |
400µL |
3.0º |
1.511 cm |
1.4-2500 |
CAP-09 |
2.0 N |
100µL |
3.0º |
0.953 cm |
5.5-10000 |
CAP-10 |
5.0 N |
170µL |
1.2º |
1.511 cm |
0.5-1000 |
Note: Viscosity ranges
shown above are for illustration. The exact range will depend upon
instrument configuration.
|

Now Offers Direct Readout In Centipoise
Why the KU-2? This
instrument is used widely for making viscosity measurements on paints/coatings
in accordance with ASTM D562.
-
Continuous sensing and display in
Krebs units, grams, and centipoise
-
Allows rapid sample measurement to
determine required consistency
-
LED Digital Display of:
-
Expanded measurement range (40 to
141 KU; 32 to 1099 g; 27 to 5274 cP)
-
Accuracy to ±1% of range
-
Reproducibility to ±0.5% of range
-
Output to parallel printer for
automatic test documentation
-
Easy to use; no weights;
simplifies an established test procedure
-
Compatible with industry
specification (ASTM D562)
-
Base accommodates standard pint,
1/2 pint, and quart cans
-
Optional air purge allows interior
of KU-2 to be pressurized with air or inert gas.
-
The optional paste spindle is
suitable for use with high consistency materials such as roller
mil pastes.
-
NIST traceable viscosity standards
available
Operation
Samples are tested in standard paint industry cans held by a fixture
located on the viscometer base. The can is filled to within
3/4" (20mm) of the top. The KU-2 operating lever has two
positions:
Up: Spindle
stationary, drive motor off
Down: Spindle rotating; sample being
measured
The displayed reading can be held by
depressing the HOLD switch at any time. With the viscometer in the
HOLD configuration, the display may be switched to compare the Krebs
unit (KU) reading with the associated gram (gm) reading, and
centipoise.
Brookfield Oil Viscosity Standards in Krebs units are NIST traceable
and are recommended for verifying calibration of the KU-2
Viscometer.
|
| |